EasyManua.ls Logo

NCE Power Pro - Page 72

NCE Power Pro
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72
SET UP THE CAB PARAMETERS
(Shortcut = PROG 6)
This allows the operator to set the Cab Address, the control method (yard or regular),
ballistic tracking of the cab and which functions are activated when the Horn/Whistle and
Bell keys are pressed.
NUMBER OF RECALLS
This adjusts the number of recall “slots” that are cycled through when the RECALL key is
pressed. Enter a number of Recalls from 1 - 6 and press ENTER. This can be set
differently for each Cab. (factory default is 2) Press ENTER to skip setting this parameter.
NUMBER 02:00PMNUMBER 02:00PM
NUMBER 02:00PMNUMBER 02:00PM
NUMBER 02:00PM
OF RECALLS: 02OF RECALLS: 02
OF RECALLS: 02OF RECALLS: 02
OF RECALLS: 02
CLEAR RECALLS
Clears the current RECALL storage. Press 1 to clear out the RECALL slots, press
ENTER to leave them alone. Press ENTER to skip setting this parameter.
CLEAR 02:00PMCLEAR 02:00PM
CLEAR 02:00PMCLEAR 02:00PM
CLEAR 02:00PM
RECALLS 1=YES:RECALLS 1=YES:
RECALLS 1=YES:RECALLS 1=YES:
RECALLS 1=YES:
ANALOG HORN CHANNEL (default is 0)
ANALOG 02:00PMANALOG 02:00PM
ANALOG 02:00PMANALOG 02:00PM
ANALOG 02:00PM
HORN CHANNEL _HORN CHANNEL _
HORN CHANNEL _HORN CHANNEL _
HORN CHANNEL _
If you have a decoder that supports a “playable” whistle such as a SoundTraxx Tsunami,
enter the analog “channel number” that the decoder uses for whistle. You can play the
whistle by holding the HORN/WHISTLE button while moving the thunbwheel. If the
channel is set to 0 no analog commands will be sent.
ANALOG AUX CHANNEL (default is 0)
ANALOG 02:00PMANALOG 02:00PM
ANALOG 02:00PMANALOG 02:00PM
ANALOG 02:00PM
AUX CHANNEL: _AUX CHANNEL: _
AUX CHANNEL: _AUX CHANNEL: _
AUX CHANNEL: _
ANALOG BIAS (default is 0)
ANALOG 02:00PMANALOG 02:00PM
ANALOG 02:00PMANALOG 02:00PM
ANALOG 02:00PM
BIAS (0-15) _BIAS (0-15) _
BIAS (0-15) _BIAS (0-15) _
BIAS (0-15) _
This is the starting point or “level” (0-15) at which analog commands will start.
ASSIGNING HORN TO FUNCTION
ASSIGN 02:00PMASSIGN 02:00PM
ASSIGN 02:00PMASSIGN 02:00PM
ASSIGN 02:00PM
HORN TO FUNC: 2HORN TO FUNC: 2
HORN TO FUNC: 2HORN TO FUNC: 2
HORN TO FUNC: 2
Enter the function number that should be activated when the Horn key is pressed. The
NMRA suggests using 2, however any function number may be used. Press ENTER to
skip setting this parameter.