CHAPTER 1 GENERAL INFORMATION
– 36 – NWA-008841-001 Rev.5.0
90ch1001.fm
Line/Trunk Card Name and Function
Continued on next page
EQUIPMENT
NAME
FUNCTIONAL
NAME
FUNCTION
PN-4LCL
[For China]
LC 4-line Analog Line Circuit Card for Single Line Telephones
Loop resistance : Maximum 600 (including telephone set)
Provides Message Waiting Lamp control, Line Test functions for
each circuit, and reverse function for only No.3 circuit.
Equipped with +80 V DC-DC on-board power supply.
PN-4LCV
[For Brazil]
LC 4-line Analog Line Circuit Card for Single Line Telephones
Loop resistance : Maximum 600 (including telephone set)
Provides Line Test function.
PN-4LCW
[For Brazil]
LC 4-line Analog Line Circuit Card for Single Line Telephones
Loop resistance : Maximum 600 (including telephone set)
Provides Message Waiting Lamp control, Line Test functions for
each circuit, and reverse function for only No.3 circuit.
Equipped with +80 V DC-DC on-board power supply.
PN-8LCAA LC 8-line Analog Line Circuit Card for Single Line Telephones
Loop resistance : Maximum 600 (including telephone set)
Provides Message Waiting Lamp control, momentary open, Line
Test functions for each circuit.
PN-8LCAB
[For China]
LC 8-line Analog Line Circuit Card for Single Line Telephones
Loop resistance : Maximum 1200 (including telephone set)
Provides Message Waiting Lamp control, momentary open, Line
Test functions for each circuit.
PN-8LCAD LC 8-line Analog Line Circuit for Single Line Telephones Provides
Caller ID Display on analog station.
Loop resistance : Maximum 600
(including telephone set)
Provides Message Waiting Lamp control, momentary open for
each circuit.
PN-8LCAE
[For China]
LC 8-line Analog Line Circuit for Single Line Telephones Provides
Caller ID Display on analog station.
Loop resistance : Maximum 1000 (including telephone set)
Provides Message Waiting Lamp control, momentary open for
each circuit.
PN-8LCAF
[For EU]
LC 8-line Analog Line Circuit for Single Line Telephones Provides
Caller ID Display on analog station.
Loop resistance : Maximum 600 (including telephone set)
Provides Message Waiting Lamp control, momentary open for
each circuit.
[Series 3800 software or later required]