CHAPTER 1 GENERAL INFORMATION
– 37 – NWA-008841-001 Rev.5.0
90ch1001.fm
Line/Trunk Card Name and Function
Continued on next page
EQUIPMENT
NAME
FUNCTIONAL
NAME
FUNCTION
PN-8LCAK LC 8-line Analog Line Circuit Card for Single Line Telephones
Loop resistance : Maximum 600 Ω (including telephone set)
Provides Message Waiting Lamp control, momentary open, Line
Test functions for each circuit.
[Series 3800 software (ver.3.0) or later required]
PN-2LDTA LDT 2-line Loop Dial Trunk Card
Loop resistance : Maximum 2500 Ω (including internal resistance
of the distant office equipment)
Equipped with –48 V DC-DC on-board power supply.
PN-4LDTA LDT 4-line Loop Dial Trunk Card
Loop resistance : Maximum 3000 Ω (including internal resistance
of the distant office equipment)
PZ-PW122 is required.
PN-4LLCB LLC 4-line Analog Long Line Circuit Card for Single Line Telephones
Provides Caller ID Display on analog station.
Loop resistance for PB/DP type:
PB : Maximum 1200 Ω
DP (20 PPS) : Maximum 1700 Ω
DP (10 PPS) : Maximum 2500 Ω
Including the internal resistance of the distant office equipment
Provides Message Waiting Lamp control, momentary open/
reverse functions for each circuit.
PZ-PW122 is required.
PN-M10 M10 Optical Fiber Interface Card
Provides optical fiber interface for T1/E1 Digital Trunk Interface
(1.5 M/2 Mbps) or Remote PIM.
Line length : 10 km (6.2 miles) or less
Line coding : CMI
PN-M13 M13 24-line Plain Old Telephone Service (POTS) Splitter Card
Used to provide data communications for HomePNA (Phoneline Net-
work Alliance)/VDSL (Very-high-data-rate Digital Subscriber Line).
PN-2ODTA ODT 2-line Out Band Dialing Trunk Card
Used as either a 2-wire E&M trunk or a 4-wire E&M trunk.
Equipped with –48 V DC-DC on-board power supply.
Both No. 0 and No. 1 circuits must be set to the same purpose (2-
wire or 4-wire) in one card.
JANUARY/26/2007
EQUIPMENT NAME AND FUNCTION