Issue 1.0 UNIVERGE SV8100
2 - 1006 SV8100 Communications Analyst Enterprise
35-02-06 SMDR Output Options –
Summary (Monthly)
Set this option to (1) to have the
SMDR report provide a monthly
summary (at midnight on the last
day of the month).
0 = Not Displayed
1 = Displayed
(default = 1)
3
35-02-07 SMDR Output Options – Toll
Charge Cost
Set this option to (1) have the
SMDR report include toll charges.
0 = Not Displayed
1 = Displayed
(default = 1)
3
35-02-08 SMDR Output Options –
Incoming Call
Enable this option (1) to have the
SMDR report include incoming
calls. If you disable this option (0),
incoming calls do not print.
0 = Not Displayed
1 = Displayed
(default = 1)
3
35-02-09 SMDR Output Options –
Extension Number or Name
Set this option (1) to have the
SMDR report include extension
numbers. Set this option (0) to
have the SMDR report include
extension names.
0 = Name
1 = Number
(default = 1)
3
35-02-10 SMDR Output Options – All Lines
Busy (ALB) Output
Determine if the All Lines Busy
(ALB) indication should be
displayed.
0 = Not Displayed
1 = Displayed
(default = 0)
3
35-02-11 SMDR Output Options – Walking
Toll Restriction Table Number
Use to set the SMDR (Station
Message Detail Recording)
walking toll restriction table number
output options for each of the eight
SMDR ports.
0 = No Output
1 = Output
(default = 1)
3
35-02-12 SMDR Output Options – DID
Table Name Output
Determine if the DID table name
should be displayed for incoming
DID calls.
0 = Not Displayed
1 = Displayed
(default = 0)
3
35-02-13 SMDR Output Options – CLI
Output When DID to Trunk
Determine if the Caller ID should
be displayed when the incoming
DID number is transferred to an
outgoing trunk.
0 = Not Displayed
1 = Displayed
(default = 0)
3
35-02-14 SMDR Output Options – Date Determine whether the date should
be displayed on SMDR reports.
This option must be set to 0 if
the trunk name is set to be
displayed in Program
35-02-03.
0 = Not Displayed
1 = Displayed
(default = 0)
3
35-02-15 SMDR Output Options – CLI/DID
Number Switching
Enter 0 to display the Caller ID
number. Determine if the Caller ID
number (0), or DID number (1)
should be displayed in the SMDR
output.
0 = CLI (CLIP)
1 = DID Number
(default = 0)
3
35-02-16 SMDR Output Options – Trunk
Name or Received Dialed
Number
Determine how the SMDR should
print incoming calls on ANI/DNIS or
DID trunks. If set to (1), ANI/DNIS
trunks can print DNIS digits. For
DID trunks, if the received number
is not defined in Program 22-11-01,
a number is not printed. If set to (0)
trunk names are printed instead
(as assigned in Program 14-01-
01).
0 = Trunk Port Name
1 = Received Dialed
Number
(default = 0)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents