UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1017
10-46-01 DT700 Series Server Information
Setup – Register Mode
0 = Normal mode:
When the phone boots up it will
report the ext. assigned in the
phone or choose the next available
extension in the system. No
password is required.
1= Auto:
If set to Auto then the SIP user
name and password must be
entered into the actual IP phone.
These settings must match 84-22/
15-05-27, or the phone will not
come on-line.
2 = Manual:
When the phone boots up it will
prompt user to enter a user id and
password before logging in. It
checks this user id/password
against 84-22/15-05-27. If there is
no match, the phone will not come
on-line.
0 = Normal
1 = Auto
2 = Manual
(default = 0)
3
15-05-27 IP Telephone Terminal Basic Data
Setup – Personal ID Index
Used when the SIP Multiline
telephone is using manual/auto
registration. Assign each phone a
unique personal index. Then go to
command 84-22 to assign the user
name and password.
0~512
(default = 0)
3
15-05-28 IP Telephone Terminal Basic Data
Setup – Addition Information
Setup
Talking Party Off Set to 0 for
Desktop Application softphone
0 = Disable
1 = Enable
(default = 0)
3
15-07-01 Programmable Function Keys Used to assign function keys to
terminals.
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
30-01-01 DSS Console Operating Mode Set the mode of the system DSS
Consoles. The available options
are Regular (Business) Mode (0),
Hotel Mode (1), ACD Monitor Mode
(2) or Business/ACD Mode (3).
0 = Business Mode
1 = Hotel Mode
2 = ACD Monitor Mode
3 = Business/ACD Mode
(default = 0)
3
30-02-01 DSS Console Extension
Assignment – Extension Number
The extension number for the
multiline terminal connected with
the DSS console (up to eight digits).
Up to eight digits.
(default not assigned)
3
30-03-01 DSS Console Key Assignment For DSS Console Chaining, assign
an Speed Dialing Service Code (or
) plus a 2-digit bin number to a DSS
Console key.
Key Number
001~500
0~99 (General Functional
Level)
97 = Door Box Access
key (additional data: 1~8
Door Box No.)
00 ~ 99
(Appearance
Functional
Level)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3