UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1037
51-15-01 Demonstration Setting Used to automatically set the
minimum setting values in NetLink.
A system reset occurs after this
command is executed.
(This program is available only
via telephone programming
and not through PC
Programming).
1 = Primary automatic
setting
2 = Secondary 1 -
automatic operation
setting
3 = Secondary 2 -
automatic operation
setting
4 = Secondary 3 -
automatic operation
setting
3
51-16-01 Net-Link System Data Replication
Mode Setting – System Data
Replication Mode
Sets the synchronous mode of the
system data. When set to 1 (Setting
Time Mode), the systems are
synchronized at the time set in Item
02 below.
When set to 2 (Interval Mode), the
systems are synchronized at regular
time intervals set in Item 03 below.
0 = Disable
1 = Setting Time Mode
2 = Interval Mode
(default = 2)
3
51-16-02 Net-Link System Data Replication
Mode Setting – System Data
Replication Time Setting
Sets the time of day that both
systems synchronize database
(when Item 01 is set to 1).
0000~2359
(default = 0000)
3
51-16-03 Net-Link System Data Replication
Mode Setting – System Data
Replication Interval Setting
Sets the time interval that both
systems synchronize database
(when Item 01 is set to 2).
15~1440 (minutes)
(default = 30 minutes)
3
51-16-04 Net-Link System Data Replication
Mode Setting – Replication Time
Stamp
Show next replication time. (default not assigned)
3
51-16-05 Net-Link System Data Replication
Mode Setting – System Data
Replication Wait Time
This sets the wait time until
replication starts when Net-Link is
created.
1~86400 (seconds)
(default = 180 seconds)
3
51-16-06 Net-Link System Data Replication
Mode Setting – System Data
Replication Interval
This program sets an interval time to
start replication to the next node
after replication to one node is
completed.
0~86400 (seconds)
(default = 1 second)
3
84-26-01 IPL Basic Setup – IP Address Assign the IP address for each DSP
on the IPLA.
xxx.xxx.xxx.xxx
Defaults:
Slot 1 = 172.16.0.20
:
Slot 4 = 172.16.0.44
3
84-26-02 IPL Basic Setup – RTP Port
Number
Assign the RTCP port number used
for each DSP on the IPLA.
0~65534
Defaults:
VoIP GW1 = 10020
VoIP GW2 = 10052
VoIP GW3 = 10084
VoIP GW4 = 10116
VoIP GW5 = 10148
VoIP GW6 = 10180
VoIP GW7 = 10212
VoIP GW8 = 10244
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3