2 - 1086 Tandem Trunking (Unsupervised Conference)
Related Features
Call Forwarding, Off-Premise
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Method A – Tandem Trunking from Conference
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
11-12-57 Service Code Setup (for Service
Access) – Tandem Trunking
If the default service code (#8) for
Tandem Trunking is not
acceptable, change the code as
required.
MLT, SLT
(default =
#8)
3
14-01-04 Basic Trunk Data Setup –
Transmit Gain Level for
Conference and Transfer Calls
Select the Transmit CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~ +15.5dB
in 0.5dB intervals)
[default = 32 (0dB)]
3
14-01-05 Basic Trunk Data Setup –
Receive Gain Level for
Conference and Transfer Calls
Select the Receive CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~ +15.5dB
in 0.5dB intervals)
[default = 32 (0dB)]
3
14-01-13 Basic Trunk Data Setup – Trunk-
to-Trunk Transfer
For each trunk that should be able
to participate in a tandem call,
enter 1.
0 = Disable
1 = Enable
(default = 1)
3
15-07-01 Programmable Function Keys (Optional) Assign a function key for
Transfer (code 06).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3