SV8100 Features and Specifications Manual 2 - 1087
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
3
20-07-11 Class of Service Options
(Administrator Level) – Forced
Trunk Disconnect (analog trunk
only)
Turns Off (0) or On (1) an
extension to use Forced Trunk
Disconnect. This allows the
extension to disconnect an
Unsupervised Conference in
progress.
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
3
20-11-14 Class of Service Options (Hold/
Transfer Service) –
Trunk-to-Trunk Transfer
Restriction
Turns Off (0) or On (1) the
Trunk-to-Trunk Transfer
Restriction. If enabled,
Trunk-to-Trunk Transfer is not
possible.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-11-21 Class of Service Options (Hold/
Transfer Service) – Restriction
for Tandem Trunking on Hang Up
Deny (1) an extension user ability
to set up a tandem call
automatically when they hang up.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-11-22 Class of Service Options (Hold/
Transfer Service) – Restricted
Unsupervised Conference
In an extensions Class of Service,
Disable (0) or Enable (1) the ability
to initiate an unsupervised
conference.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-08 Class of Service Options
(Supplementary Service) –
Conference
In an extension Class of Service,
enable (1) or disable (0) the
extension ability to initiate a
conference.
0 = Disable
1 = Enable
(default = 1 for
COS 1~15)
3
20-13-10 Class of Service Options
(Supplementary Service) –
Barge-In Monitor
Enables the extension Barge-In
Mode to be speech mode (0) or
Monitor mode (1).
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
24-02-07 System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
This timer starts when a trunk
begins talking with another trunk
(for example: Trunk-to-Trunk
Transfer, outgoing from trunk,
Tandem Trunking).
0~64800 (seconds)
(default = 1800 seconds)
3
24-02-10 System Options for Transfer –
Disconnect Trunk-to-Trunk
This timer starts after the
Trunk-to-Trunk warning tone is
heard.
0~64800 (seconds)
(default = 0 seconds)
3
25-07-07 System Timers for VRS/DISA –
Ling Conversation Warning Tone
Time
Determine the time a DISA caller
or a Tandem Trunking conversation
can talk before the Long
Conversation tone is heard.
0~64800 (seconds)
(default = 1800 seconds)
3
25-07-08 System Timers for VRS/DISA –
Long Conversation Disconnect
Time
This timer determines how long the
system waits before disconnecting
a call after the Long Conversation
tone is heard.
0~64800 (seconds)
(default = 30 seconds)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents