Issue 1.0 UNIVERGE SV8100
2 - 1088 Tandem Trunking (Unsupervised Conference)
Method B – Tandem Trunking with Transfer Key
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
14-01-04 Basic Trunk Data Setup –
Transmit Gain Level for
Conference and Transfer Calls
Select the Transmit CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~
+15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
3
14-01-05 Basic Trunk Data Setup – Receive
Gain Level for Conference and
Transfer Calls
Select the Receive CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~
+15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
3
14-01-13 Basic Trunk Data Setup –
Trunk-to-Trunk Transfer
For each trunk, enter 1 to enable
loop supervision.
0 = Disable
1 = Enable
(default = 1)
3
15-07-01 Programmable Function Keys Assign a function key for Transfer
(code 06).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-07-11 Class of Service Options
(Administrator Level) – Forced
Trunk Disconnect (analog trunk
only)
Turns Off (0) or On (1) an extension
to use Forced Trunk Disconnect.
This allows the extension to
disconnect an Unsupervised
Conference in progress.
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
3
20-11-14 Class of Service Options (Hold/
Transfer Service) –
Trunk-to-Trunk Transfer
Restriction
Turns Off (0) or On (1) the Trunk-to-
Trunk Transfer Restriction. If
enabled, Trunk-to-Trunk Transfer is
not possible.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-11-21 Class of Service Options (Hold/
Transfer Service) – Restriction for
Tandem Trunking on Hang Up
Deny (1) an extension user’s ability
to set up a tandem call
automatically when they hang up.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-10 Class of Service Options
(Supplementary Service) – Barge-
In Monitor
Enables the extension Barge-In
Mode to be speech mode (0) or
Monitor mode (1).
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
24-02-07 System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
This timer starts when a trunk
begins talking with another trunk
(for example: Trunk-to-Trunk
Transfer, outgoing from trunk,
Tandem Trunking).
0~64800 (seconds)
(default = 1800
seconds)
3