Issue 1.0 UNIVERGE SV8100
2 - 88 Automatic Release
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
14-02-09 Analog Trunk Data Setup – Busy
Tone Detection
This option Enables/Disables Busy
Tone Detection.
0 = Disable (No)
1 = Enable (Yes)
(default = 1)
3
14-02-14 Analog Trunk Data Setup – Loop
Start/Ground Start
This option identifies the analog
trunk as either loop or ground start.
0 = Loop Start (Loop)
1 = Ground Start (Ground)
(default = 0)
3
80-04-01 Call Progress Tone Detector
Setup – Detection Level
Use this option to set the Detection
Level.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
3