Issue 1.0 UNIVERGE SV8100
2 - 1102 TAPI Compatibility
Operation
TAPI operation is automatic once programmed in the telephone system and enabled in the PC TAPI
application, unless a headset is used.
Using the Headset with Automatic Answer:
1. With the multiline terminal in an idle state, press the Help key.
2. Press the Headset key (Program 15-07 or SC 751: 05) twice.
3. Press the Exit key to return the display to idle.
The Headset key blinks when Automatic Headset is activated.
To cancel Automatic Headset, repeat these steps.
To redirect calls to the headset and disable the hookswitch (required for some TAPI features):
1. With the multiline terminal in an idle state, press the Help key.
2. Press the Headset key (Program 15-07 or SC 751: 05) twice.
3. Press the Exit key to return the display to idle.
The Headset key blinks when Automatic Headset is activated.
To cancel Automatic Headset, repeat these steps.
4. Press the Headset key (Program 15-07 or SC 751: 05) to go Off-Hook.
10-12-03 CD-CP00-AU Network Setup –
Default Gateway
Assign the default gateway IP
address for the CD-CP00-AU.
0.0.0.0 ~
126.255.255.254
128.0.0.1 ~
191.254.255.254
192.0.0.1 ~
223.255.255.254
(default = 0.0.0.0)
3
10-20-01 LAN Setup for External
Equipment – TCP Port
Use to define the TCP port/
address/etc. for communicating to
external equipment.
0~65535
default:
External Device 1 (CTI)
= 0
External Device 2 (ACD
MIS) = 4000
External Device 5
(SMDR Output) = 0
External Device 6 (DIM
Output) = 0
External Device 11
(O&M Server) = 8010
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3