Issue 1.0 UNIVERGE SV8100
2 - 1136 Trunk Queuing/Camp-On
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
11-12-04 Service Code Setup (for Service
Access) – Set Camp-On
Customize the Service Code, which
is to be used for setting Camp-On.
MLT, SLT
(default = 750)
3
11-12-05 Service Code Setup (for Service
Access) – Cancel Camp-On
Customize the Service Code, which
is to be used for cancelling Camp-
On.
MLT, SLT
(default = 770)
3
11-16-05 Single Digit Service Code Setup –
Camp-On
Customize the 1-digit Service
Code used for setting Camp-On.
(default = #)
3
15-07-01 Programmable Function Keys Assign a function key for Trunk
Queuing and Trunk Camp-On
(code 35).
Trunk Groups: 1~100
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
20-01-08 System Options – Trunk Queuing
Callback Time
Set the Trunk Queuing Callback
Time. Trunk Queuing Callback
rings an extension for this interval.
0~64800 (seconds)
(default = 15 seconds)
3
20-01-09 System Options – Callback/Trunk
Queuing Cancel Time
Set the Callback/Trunk Queuing
Cancel Time. The system cancels
an extension Callback or Trunk
Queuing request after this interval.
0~64800 (seconds)
(default = 64800
seconds)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-11-07 Class of Service Options (Hold/
Transfer Service) – Transfer
Without Holding
Turns Off or On an extension ability
to use Transfer Without Holding.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-29-01 Timer Class for Extensions Assign the timer class (0~15) to
each extension for each Night
mode. This entry includes virtual
extension number.
0~15
0 = Not assigned
(default = 0)
3