Issue 1.0 UNIVERGE SV8100
2 - 1172 UM8000 Mail
80-03-06 DTMF Tone Receiver Setup –
Backward twist level
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
0~9
(1dB ~ 10dB)
default:
All Receivers = 9
3
80-03-07 DTMF Tone Receiver Setup – ON
detect time
Use this option to define the On
dectection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
80-03-08 DTMF Tone Receiver Setup – OFF
detect time
Use this option to define the Off
dectection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
80-04-01 Call Progress Tone Detector
Setup – Detection Level
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the Detection
Level.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
3
80-04-02 Call Progress Tone Detector
Setup – Min. Detection Level
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the minimum
detection level.
0~15
detect level 0:
–15dBm(0) to
–30dBm(15)
detect level 1:
–30dBm(0) to
–45dBm(15)
detect level 2:
–40dBm(0) to
–55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents