UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1173
80-04-03 Call Progress Tone Detector
Setup – S/N Ratio
Define the various levels and timers
for the Call Progress Tone
Detector.
0~4 (0dB ~ -20dB)
default:
Type 1 (DT) – 4
(-20dB)
Type 2 (BT) – 4
(-20dB)
Type 3 (RBT) – 4
(-20dB)
Type 4, Type 5 – 0
3
80-04-04 Call Progress Tone Detector
Setup – No Tone Time
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set No Tone
Time.
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
3
80-04-05 Call Progress Tone Detector
Setup – Pulse Count
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the Pulse
Count.
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
3
80-04-06 Call Progress Tone Detector
Setup – ON minimum time
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the minimum
On time.
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 9
(300ms)
Type 2 (BT) – 9
(300ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
3
80-04-07 Call Progress Tone Detector
Setup – ON maximum time
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the maximum
On time.
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 0
Type 2 (BT) – 14
(450ms) [ET]
Type 3 (RBT) – 40
1230ms)
Type 4, Type 5 – 0
3
80-04-08 Call Progress Tone Detector
Setup – OFF minimum time
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the minimum
Off time.
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 9
(300ms)
Type 3 (RBT) – 83
(2520ms)
Type 4, Type 5 – 0
3
Program
Number
Program Name Description/Comments Assigned Data
Level