UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1269
80-03-06 DTMF Tone Receiver Setup –
Backward twist level
Use to define the various backward
twist levels for the DTMF Tone
Receiver.
0~9 (1dB ~ 10dB)
default:
All Receivers = 9
3
80-03-07 DTMF Tone Receiver Setup – ON
detect time
Use to define the on detect time for
the DTMF Tone Receiver.
1~255 (15+ 15 ms ~
3825 ms)
default:
All Receivers = 1
3
80-03-08 DTMF Tone Receiver Setup – OFF
detect time
Use to define the off detect time for
the DTMF Tone Receiver.
1~255 (15+ 15 ms ~
3825 ms)
default:
All Receivers = 1
3
80-04-01 Call Progress Tone Detector
Setup – Detection Level
Use to define the detection levels
for the Call Progress Tone Detector.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
3
80-04-02 Call Progress Tone Detector
Setup – Min. Detection Level
Use to define the minimum
detection levels for the Call
Progress Tone Detector.
0~15
detect level 0 : –15dBm
(0) to –30dBm(15)
detect level 1 : –30dBm
(0) to –45dBm(15)
detect level 2 : –40dBm
(0) to –55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
3
80-04-03 Call Progress Tone Detector
Setup – S/N Ratio
Use to define the S/N ratio for the
Call Progress Tone Detector.
0~4 (0dB ~ -20dB)
default:
Type 1 (DT) – 4
(-20dB)
Type 2 (BT) – 4
(-20dB)
Type 3 (RBT) – 4
(-20dB)
Type 4, Type 5 – 0
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3