Issue 1.0 UNIVERGE SV8100
2 - 1270 Voice Mail Integration (Analog)
80-04-04 Call Progress Tone Detector
Setup – No Tone Time
Use to define the no tone time for
the Call Progress Tone Detector.
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
3
80-04-05 Call Progress Tone Detector
Setup – Pulse Count
Use to define the pulse count for
the Call Progress Tone Detector.
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
3
80-04-06 Call Progress Tone Detector
Setup – ON minimum time
Use to define the on minimum time
for the Call Progress Tone Detector.
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 9
(300ms)
Type 2 (BT) – 9 (300ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
3
80-04-07 Call Progress Tone Detector
Setup – ON maximum time
Use to define the on maximum time
for the Call Progress Tone Detector.
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 0
Type 2 (BT) – 14
(450ms) [ET]
Type 3 (RBT) – 40
1230ms)
Type 4, Type 5 – 0
3
80-04-08 Call Progress Tone Detector
Setup – OFF minimum time
Use to define the off minimum time
for the Call Progress Tone Detector.
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 9 (300ms)
Type 3 (RBT) – 83
(2520ms)
Type 4, Type 5 – 0
3
80-04-09 Call Progress Tone Detector
Setup – OFF maximum time
Use to define the off maximum time
for the Call Progress Tone Detector.
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 14
(450ms)
Type 3 (RBT) – 115
(3480ms)
Type 4, Type 5 – 0
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents