UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1315
IP Phone Configuration:
84-26-03 IPL Basic Setup – RTCP Port
Number (RTP Port Number + 1)
Use to set the IP address of IPL and
the port.
0~65534
Defaults:
VoIP GW1 = 10021
VoIP GW2 = 10053
VoIP GW3 = 10085
VoIP GW4 = 10117
VoIP GW5 = 10149
VoIP GW6 = 10181
VoIP GW7 = 10213
VoIP GW8 = 10245
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
15-01-01 Basic Extension Data Setup –
Extension Name
Define the extension/virtual extension
name.
Up to 12 characters
Default:
STA 101 = Ext 101
STA 102 = Ext 102, etc.
3
15-05-02 IP Telephone Terminal Basic Data
Setup – IP Phone Fixed Port
Assignment
MAC Address of registered MLT SIP
phone is stored and/or can input the
MAC address of an MLT SIP phone
so when it comes online it will be
provided with the extension in which
the MAC address matches.
MAC address
00-00-00-00-00-00 to
FF-FF-FF-FF-FF-FF
(default =
00-00-00-00-00-00)
3
15-05-07 IP Telephone Terminal Basic Data
Setup – Using IP Address
Use this program to review the
registered IP Phones IP Address
[Informational Only].
0.0.0.0 ~
255.255.255.255
(default = 0.0.0.0)
3
15-05-15 IP Telephone Terminal Basic Data
Setup – CODEC Type
Use this program to set the registered
IP Phone Codec type – Reference
Program 84-11 Dterm IP Codec
Basic Information.
1-Type 1
2-Type 2
3-Type 3
4-Type 4
5-Type 5
(default = 1)
3
15-05-16 IP Telephone Terminal Basic Data
Setup – Authentication Password
Assign the authentication password
for SIP single line telephones.
Up to 24 characters
(default not assigned)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3