UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 117
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
11-12-08 Service Code Setup (for Service
Access) – Barge-In
Determine what the service code
should be for an internal party to
use the Barge-In feature.
MLT, SLT
(default = 710)
3
11-16-02 Singl;e Digit Service Code Setup
– Barge-In
Use this option to set up Item 02 for
single digit Barge-In. For example,
you can assign Item 02 to use digit
5 for Barge-In. This allows you to
program a function key with an
extension number plus the Barge-In
code (i.e., 5). This allows one-
touch access to the Barge-In
feature for extension.
(default not assigned)
3
15-07-01 Programmable Function Keys Assign a function key for Barge-In
(code 34).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-13-10 Class of Service Options
(Supplementary Service) –
Barge-In Monitor
Enables the extension Barge-In
Mode to be Speech mode (0) or
Monitor mode (1).
0 = Off
1 = On
(default: 0 for COS
1~15)
3
20-13-15 Class of Service Options
(Supplementary Service) –
Barge-In, Initiate
Turns Off (0) or On (1) an extension
user ability to barge-in on other's
calls.
0 = Speech
1 = Monitor
(default: 0 for COS
1~15)
3