Issue 1.0 UNIVERGE SV8100
2 - 118 Barge-In
Operation
To Barge-In after calling a busy extension:
The time in Program 21-01-03 must expire before you can Barge-In.
1. Call a busy extension.
2. Press Barge-In key (Program 15-07-01 or SC 751: 34).
To Barge-In without first calling the busy extension:
1. Pick up the handset or press Speaker.
2. Dial 710.
- OR -
Press Barge-In key (Program 15-07-01 or SC 751: 34).
20-13-16 Class of Service Options
(Supplementary Service) –
Barge-In, Receive
In an extension Class of Service,
turns On (1) or Off (0) Barge-In at
the receiving extension (i.e., Barge-
In receive).
0 = Off
1 = On
(default: 0 for COS
1~15)
3
20-13-17 Class of Service Options
(Supplementary Service) –
Barge-In Tone/Display (Intrusion
Tone)
In an extension Class of Service,
turns On (1) or Off (0) the Barge-In
(Intrusion) Tone. If disabled, this
also turns off the Barge-In display at
the called extension.
0 = Off
1 = On
(default: 1 for COS
1~15)
3
20-13-32 Class of Service Options
(Supplementary Service) –
Multiple Barge-Ins
In an extension Class of Service,
Allow (1) or Deny (0) the extension
ability to deny multiple users Barge-
In to their conversation.
0 = Off
1 = On
(default: 0 for COS
1~15)
3
20-14-11 Class of Service Options for
DISA/E&M – DISA/Tie Trunk
Barge-In
In an extension Class of Service,
Enable (1) or Disable (0) a DISA or
tie trunk user from using the Barge-
In feature.
0 = Off
1 = On
(default: 0 for COS
1~15)
3
20-18-07 Service Tone Timers – Intrusion
Tone Repeat Time
After a user barges in, the system
repeats the Barge-In tone after this
interval.
Intrusion tone is not available if
Program 20-13-17 is set to disable
(0).
0~64800 seconds
(default = 0 seconds)
3
21-01-03 System Options for Outgoing
Calls – Trunk Interdigit Time
(External)
Program how long an extension
must wait before using the Barge-In
feature can be used on a call (this
timer waits until it expires before
putting a call in a talk state). This
timer also affects Voice Over.
0~64800 seconds
(default = 5 seconds)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3