EasyManua.ls Logo

NEC Univerge SV8100 - Page 152

NEC Univerge SV8100
1386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 1.0 UNIVERGE SV8100
2 - 128 Call Appearance (CAP) Keys
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-11-19 Class of Service Options (Hold/
Transfer Service) – Hold/
Extended Park
Determine whether an extension
Class of Service should allow
normal or extended Park
(0 = Normal for Program 24-01-06,
1 = Extended for Program
24-01-07).
0 = Off
1 = On
(default = 0 for COS
1~15)
3
24-01-01 Hold Recall Time A call on Hold recalls the extension
that placed it on Hold after this time.
This time works with the Hold
Recall Callback Time.
0~64800 (seconds)
(default = 90)
3
24-01-02 System Options for Hold – Hold
Recall Callback Time
A call that is parked longer than the
programmed interval recalls the
extension where it was initially
parked.
0~64800 (seconds)
(default = 0)
3
24-01-03 Exclusive Hold Recall Time A call left on Exclusive Hold recalls
the extension that placed it on Hold
after this time.
0~64800 (seconds)
(default = 90)
3
24-01-04 Exclusive Hold Recall Callback
Time
An Exclusive Hold Recall rings an
extension for this time. If not picked
up, the call goes back on System
Hold.
0~64800 (seconds)
(default = 0)
3
24-01-05 Forced Release of Held Call Depending on the setting of
Program 14-01-16, the system
disconnects calls on Hold longer
than this time.
0~64800 (seconds)
(default = 1800)
3
24-01-06 System Options for Hold – Park
Hold Time - Normal
Set the Park Hold Time (0~64800
seconds). A call that is parked
longer than the programmed time
recalls the extension where it was
initially parked.
Refer to Flexible System
Numbering on page 2-515 for
setting Flexible Timeouts for Class
of Service.
0~64800 (seconds)
(default = 90 seconds)
3
24-01-07 System Options for Hold – Park
Hold Time - Extended (Recall)
Set the Extended Park Hold Time
(0~64800 seconds). A call that is
parked longer than the programmed
time recalls the extension where it
was initially parked.
0~64800 (seconds)
(default = 300
seconds)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals