EasyManua.ls Logo

NEC Univerge SV8100 - Page 165

NEC Univerge SV8100
1386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 141
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
10-09-01 DTMF and Dial Tone Circuit
Setup
Allocate the circuits on the
CD-CP00-AU ETUs for either
DTMF receiving or dial tone
detection. Program 14-01-13 Basic
Trunk Data Setup – Loop
Supervision Enable (1) loop
supervision for each trunk that
should be able to use Call
Forwarding – Centrex.
0 = Common Use
1 = Extension Only
2 = Trunk Only
Default:
Circuit/Resource
01~08 = 1 (Extensions)
Circuit/Resource
09~32 = 2 (Trunks)
Circuit/Resource
33~96 = 0 (Not Used)
Circuit/Resource
97~160 = 0 (Common)
When PZ-BS10 is
installed, 97~160 are
available
3
11-11-45 Service Code Setup (for Setup/
Entry Operation) – Set/Cancel
Call Forward All (Split)
Used to assign the Call Forward All
Split Service Code.
MLT, SLT
(default not assigned)
3
11-11-46 Service Code Setup (for Setup/
Entry Operation) – Set/Cancel
Call Forward Busy (Split)
Used to assign the Call Forward
Busy Split Service Code.
MLT, SLT
(default not assigned)
3
11-11-47 Service Code Setup (for Setup/
Entry Operation) – Set/Cancel
Call Forward No Answer (Split)
Used to assign the Call Forward No
Answer Split Service Code.
MLT, SLT
(default not assigned)
3
11-11-48 Service Code Setup (for Setup/
Entry Operation) – Set/Cancel
Call Forward Busy/No Answer
(Split)
Used to assign the Call Forward
Busy No Answer Split Service
Code.
MLT, SLT
(default not assigned)
3
14-01-13 Basic Trunk Data Setup –
Trunk-to-Trunk Transfer
Use this option to Enable or Disable
loop supervision for the trunk.
0 = Disable (No)
1 = Enable (Yes)
(default = 1)
3
14-04-01 Behind PBX Setup Indicate if the trunk is installed
behind a PBX (1) or not (0). There
is one item for each of the Night
Service Modes.
0 = Stand Alone
(Trunk)
1 = Behind PBX (PBX)
2 = Not Used
3 = CTX assume 9
(default = 0)
3