UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 193
15-02-12 Multiline Telephone Basic Data
Setup – Off-Hook Ringing
Use this option to set the telephone
Off-Hook signaling.
0 = Muted Off-Hook
Ringing
1 = No Off-Hook
Ringing
2 = Not Used
3 = Beep in Speaker
(SP)
4 = Beep in Handset
(HS)
5 = Speaker & Handset
Beep
(default = 5)
3
15-07-01 Programmable Function Keys Use to assign a function for
Camp-On (code 35). This key is
also the Callback key.
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
3
20-01-08 System Options – Trunk
Queuing Callback Time
Set the Trunk Queuing callback
time. A Trunk Queuing Callback
rings an extension for this interval.
0~64800 (seconds)
(default = 15 seconds)
3
20-01-09 System Options – Callback/
Trunk Queuing Cancel Time
The system cancels an extension
Callback or Trunk Queueing
request after this interval.
0~64800 (seconds)
(default = 64800
seconds)
3
20-03-01 System Options for Single Line
Telephones – SLT Call Waiting
for Answer Mode
For a busy single line (500/2500
type) telephone, set the mode used
to answer a camped-on trunk call.
For ESL sets, enabling this option
(1) allows the user to dial Service
Code for Voice Mail Conversation
Record.
0 = Hookflash
(Hooking)
1 = Hookflash +
Service Code 654
(default = 0)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3