Issue 1.0 UNIVERGE SV8100
2 - 208 Caller ID
An extension user can display the Caller ID information for a call in Park if Automatic
Handsfree in Program 15-02-08 is set to 0 (Preselect).
An extension user can display the Caller ID information for multiple incoming calls without
answering the call by pressing the line key if Automatic Handsfree in Program 15-02-08 is
set to 0 (Pre-select).
Caller ID information outputs on the SMDR report.
The system can send Caller ID digits to the voice mail if allowed in Program 14-02-10.
When more than 20 characters set in Program 20-20 : Message Setup for Non-Caller ID
Data, either the first or last character is missing (based on the entry in Program 20-19-01).
If Program 20-09-06: Class of Service Options (Incoming Call Service): Incoming Time
Display is set to 1 (On), the first line displays the time and date.
When you shut down the system, incoming history data is cleared. But you can back up the
history data by pressing Speaker +
# # 9.
Program 15-07-01 button (63) when enabled, removes the CPN from the setup message
when making an outbound ISDN call, this is a toggle enable/disable button and can be used
on a Call-by-Call basis. Programs 14-01-20, 14-01-21 and 20-08-15 are used for copper
trunks only and can be set only per trunk/Class of Service.
SLT users cannot block an incoming call based on the incoming Caller ID information on a
station-by-station basis.
Default Setting
Disabled
System Availability
Terminals
All Multiline Terminals with a display and Single Line Telephones equipped to receive Caller ID.
Required Component(s)
CD-4COTC with PZ-4COTG Daughter Board
CD-2BRIA with PZ-2BRIA Daughter Board
CD-PRTA