UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 389
Programmable Function Keys
Ring Groups
Transfer
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
15-07-01 Programmable Function Keys To have the DIL ring a key, program
a line key for the DIL trunk.
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-09-01 Class of Service Options
(Incoming Call Service) –
Second Call for DID/DISA/DIL/
E&M Override
Turns Off or On the extension ability
to receive a second call from a DID,
DISA, DIL, or tie line caller.
With this option set to 1, the
destination extension must be
busy for a second DNIS caller
to ring through. If the
destination extension does not
have a trunk or CAP key
available for the second call
and a previous call is ringing
the extension but has not yet
been answered, the second
caller hears busy regardless of
this program setting.
0 = Off
1 = On
(default = 1 for
COS 1~15)