UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 441
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
10-03-01
(1)
ETU Setup (DLC PKG Setup)
Terminal Type (B1)
Use to setup and confirm the Basic
Configuration data for terminal type
(B1).
0 = Not set
1 = Multiline Terminal
2 = SLT Adapter
3 = Bluetooth Cordless
Handset
6 = PGD (Paging)
7 = PGD (Tone Ringer)
8 = PGD (Doorbox)
9 = PGD (ACI)
10 = DSS Console
11 = -- Not Used --
(default = 0))
3
10-03-06 ETU Setup (DLC PKG Setup) –
Terminal Type (B2)
Use to setup and confirm the Basic
Configuration data for terminal type.
For DLC package support, set the
terminal type to 8 [PGD (for Door
Box)]. First set 10-03-01 to 0 with
no device plugged into that port,
then plug the device in and the
system should recognize it as a
door box and then set Program
10-03-06.
0 = Not set
6 = PGD(2)-U( ) ADP
(Paging)
7 = PGD(2)-U( ) ADP
(Tone Ringer)
8 = PGD(2)-U( ) ADP
(Door Box)
9 = PGD(2)-U( ) ADP
(ACI)
12 = APR (B2 Mode)
(default = 0)
3
10-05-01 General Purpose Relay Setup –
Slot No. Physical Port of DLC
Sensor Circuit No.
Define which Relay circuits (5~8) on
a PGD(2)-U( ) ADP Adapter are
used for General Purpose Relay.
Slot No: 0~24
DCLA Port: 0~16
Relay No: 0, 5~8
After each entry,
pressing the
Transfer Key
advances to the
next entry.
(default = 0 - 0 - 0)
3
11-12-36 Service Code Access (for
Service Access) – Door Box
Access
If the service code for Doorphone
Access is not acceptable, change it
here.
MLT, SLT
(default = 702)
3
15-07-01 Programmable Function Keys Assign a function key for External
Call Forward by Doorphone (Code
54).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
3
32-01-01 Door Box Timers – Door Box
Answer Time
Set the time a user has to answer
the Door Box chimes.
0~64800 (seconds)
(default = 30 seconds)
3
32-01-02 Door Box Timers – Door Lock
Cancel Time
Set the time the Door Box strike
stays open when the single line
telephone user hookflashes or a
multiline terminal user presses
Recall.
0~64800 (seconds)
(default = 10 seconds)
3