UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 447
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
81-10-07 COI Initial Data Setup –
Hookflash Time Selection 1
Set the Flash duration (20 mS~5.0
sec) for analog trunk [COI( )-U( )
ETU] circuits.
0 = 20 ms
1 = 40 ms
2 = 60 ms
3 = 80 ms
4 = 100 ms
5 = 140 ms
6 = 160 ms
7 = 200 ms
8 = 400 ms
9 = 600 ms
10 = 800 ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 4 (100ms)
All Trunks]
3
81-10-08 COI Initial Data Setup –
Hookflash Time Selection 2
Set the open loop disconnect
duration (20 mS~5.0 sec) for
analog trunk [COI( )-U( ) ETU]
circuits.
0 = 20 ms
1 = 40 ms
2 = 60 ms
3 = 80 ms
4 = 100 ms
5 = 140 ms
6 = 160 ms
7 = 200 ms
8 = 400 ms
9 = 600 ms
10 = 800 ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 14 (3.0
seconds)]
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3