UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 539
21-01-03 System Options for Outgoing
Calls – Trunk Interdigit Time
(External)
Program how long an extension
must wait before using the Barge-In
feature can be used on a call (this
timer waits until it expires before
putting a call in a talk state). This
timer also affects Voice Over.
0~64800 seconds
(default = 5 seconds)
3
21-01-09 System Options for Outgoing
Calls – Ringdown Extension
Timer (Hotline Start)
After the user lifts the handset, the
extension automatically calls the
ringdown destination after this
interval. A setting of 0 immediately
rings the programmed extension.
Any other setting delays the
ringdown the number of seconds
programmed.
0~64800 seconds
(default = 0 seconds)
3
22-01-03 System Options for Incoming
Calls – Ring No Answer Alarm
Time
Set the Ring No Answer Alarm
interval. If a trunk rings a multiline
terminal longer than this interval,
the system changes the ring
cadence.
0~64800 (seconds)
(default = 60 seconds)
3
22-01-04 System Options for Incoming
Calls – DIL No Answer Recall
Time
A DIL that rings its programmed
destination longer than this interval
diverts to the DIL No Answer Ring
Group (set in Program 22-08).
0~64800 (seconds)
(default = 0 seconds)
3
22-01-06 System Options for Incoming
Calls – DID Ring-No-Answer
Time
Set the DID Ring No Answer (RNA)
Intercept time (0~64800 seconds).
In systems with RNA Intercept, the
DID call rings the destination
extension for this time, and then
rings Intercept Ring Group.
0~64800 (seconds)
(default = 20 seconds)
3
24-01-01 System Options for Hold – Hold
Recall Time
Set the Hold Recall Time. A call on
Hold recalls the extension that
placed it on Hold after this time.
0~64800 (seconds)
(default = 90 seconds)
3
24-01-02 System Options for Hold – Hold
Recall Callback Time
Set the Hold Recall Callback Time.
A trunk recalling from Hold rings an
extension for this time.
0~64800 (seconds)
(default = 0 seconds)
3
24-01-03 System Options for Hold –
Exclusive Hold Recall Time
Set the Exclusive Hold Recall Time.
A call on Exclusive Hold recalls the
extension that placed it on Hold
after this time.
0~64800 (seconds)
(default = 90 seconds)
3
24-01-04 System Options for Hold –
Exclusive Hold Recall Callback
Time
Set the Hold Recall Time. A trunk
recalling from Hold rings an
extension for this time. If still
unanswered, the call changes to
System Hold.
0~64800 (seconds)
(default = 0 seconds)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3