Issue 1.0 UNIVERGE SV8100
2 - 34 Alarm Reports
Operation
To use this feature at any terminal:
The user must be logged in with an Installer (IN) level password as defined in Program 90-02.
10-12-03 CD-CP00-AU Network Setup –
Default Gateway
Assign the default gateway IP
address for the CD-CP00-AU.
0.0.0.0 ~
126.255.255.254
128.0.0.1 ~
191.254.255.254
192.0.0.1 ~
223.255.255.254
(default = 0.0.0.0)
3
90-11-02 System Alarm Report – Report
Method
When Alarm Reports are to be
e-mailed, set this option to 1. This
program has higher priority than
Program 90-12-06.
0 = No Report
1 = E-mail Address
(default = 0)
3
90-11-06 System Alarm Report – SMTP
Host Name
When Alarm Reports are to be
e-mailed, set the SMTP name (for
example, smtp.yourisp.com).
Contact your ISP (Internet Service
Provider) for the correct entry if
needed.
Up to 255 characters
(default not assigned)
3
90-11-07 System Alarm Report – SMTP
Host Port Number
When Alarm Reports are to be
e-mailed, set the SMTP host port
number. Contact your ISP (internet
service provider) for the correct entry
if needed.
0 ~ 65535
(default = 25)
3
90-11-08 System Alarm Report – To Email
Address
When Alarm Reports are to be
e-mailed, set this e-mail address to
which the report should be sent.
Up to 255 characters
(default not assigned)
3
90-11-09 System Alarm Report – Reply
Address
When Alarm Reports are to be
e-mailed, set the e-mail address
where replies should be e-mailed.
Up to 255 characters
(default not assigned)
3
90-11-10 System Alarm Report – From
Address
When Alarm Reports are to be
e-mailed, set this e-mail address for
the station sending the report.
Up to 255 characters
(default not assigned)
3
90-11-11 System Alarm Report – DNS
Primary Address
When Alarm Reports are to be
e-mailed, set the DNS primary
address.
0.0.0.0 ~
255.255.255.255
(default = 0.0.0.0)
3
90-11-12 System Alarm Report – DNS
Secondary Address
When Alarm Reports are to be
e-mailed, set the DNS secondary
address.
0.0.0.0 ~
255.255.255.255
(default = 0.0.0.0)
3
90-11-13 System Alarm Report – Customer
Name
When Alarm Reports are to be
e-mailed, enter a name to identify the
particular system.
Up to 255 characters
(default not assigned)
3
90-25-01 System Alarm Report CC Mail
Setup – CC Mail Address
Define the mail address to receive
the system alarm report CC Mail
setup.
Up to 255 characters
(default not assigned)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents