UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 605
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
11-11-13 Service Code Setup (for Setup/
Entry Operation) – Display
Language Selection for Multiline
Terminal
Select the service code which can
be used at an extension to change
the displayed language on a
multiline terminal display.
MLT
(default = 678)
3
15-02-01 Multiline Telephone Basic Data
Setup – Display Language
Selection
(To select options 8~10, press
either 8 or Recall, then press line
keys 1~3. Key 1 is option 8, Key
2 is option 9, and Key 3 is option
10.)
Select the language to be displayed
on a multiline terminal display.
0 = Japanese
1 = English
2 = German
3 = French
4 = Italian
5 = Spanish
6 = Dutch
7 = Portuguese
8 = Norwegian
9 = Danish
10 = Swedish
11 = Turkish
12 = Latin American
Spanish
13 = Romanian
14 = Polish
(default = 1)
3
20-06-01 Class of Service for Extensions Assign Class of Service (1~15) for
extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-08-01 Class of Service Options
(Outgoing Call Service) –
Intercom Calls
Turns Off or On Intercom calling for
the extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-08-11 Class of Service Options
(Outgoing Call Service) – Protect
for the Call Mode Switching from
Caller
When an extension is set to ring
mode for ICM calls, enabling this
option prevents callers from
changing the call to voice announce
mode.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-11-07 Class of Service Options (Hold/
Transfer Service) – Transfer
Without Holding
Turns Off or On an extension ability
to use Transfer Without Holding.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-22 Class of Service Options
(Supplementary Service) – Busy
Status Display (Called Party
Status)
Turns Off or On the ability to display
the detailed state of the called
party.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-17-01 Operator Extension – Operator’s
Extension Number
Define the extension numbers
which are to be used by operators.
Up to eight digits
(default = 101)
3