UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 651
84-01-12 H.323 Trunk Basic Information
Setup – G.723 VAD mode
Use to define the G.723 VAD mode
for H.323.
0 = Disable
1 = Enable
(default = 0)
3
84-01-15 H.323 Trunk Basic Information
Setup – Jitter Buffer Mode
Use to define the jitter buffer mode
for H.323.
1 = Fixed
2 = Self adjusting
(silence period)
3 = Self adjusting
(default = 3)
3
84-01-16 H.323 Trunk Basic Information
Setup – G.711 Jitter Buffer (min)
Use to define the G.711 jitter buffer
(minimum) for H.323.
0~160
(default = 30)
3
84-01-17 H.323 Trunk Basic Information
Setup – G.711 Jitter Buffer
(average)
Use to define the G.711 jitter buffer
(average) for H.323.
0~160
(default = 60)
3
84-01-18 H.323 Trunk Basic Information
Setup – G.711 Jitter Buffer (max)
Use to define the G.711 jitter buffer
(maximum) for H.323.
0~160
(default = 120)
3
84-01-19 H.323 Trunk Basic Information
Setup – G.723 Jitter Buffer (min)
Use to define the G.723 jitter buffer
(minimum) for H.323.
0~270
(default = 30)
3
84-01-20 H.323 Trunk Basic Information
Setup – G.723 Jitter Buffer
(average)
Use to define the G.723 jitter buffer
(average) for H.323.
0~270
(default = 60)
3
84-01-21 H.323 Trunk Basic Information
Setup – G.723 Jitter Buffer (max)
Use to define the G.723 jitter buffer
(maximum) for H.323.
0~270
(default = 120)
3
84-01-22 H.323 Trunk Basic Information
Setup – VAD Threshold
Use to define the VAD threshold for
H.323.
0~30 (-19db~ +10db
and self adjustment)
0 = Self adjustment
1 = -19db (-49dbm)
:
20 = 0db (-30dbm)
:
29 = 9db (-21dbm)
30 = 10db (-20dbm)
(default = 20)
3
84-01-23 H.323 Trunk Basic Information
Setup – Idle Noise Level
Use to define the idle noise level for
H.323.
-5000dbm ~ -7000dbm
(default = 7000)
3
84-01-24 H.323 Trunk Basic Information
Setup – Echo Canceller Mode
Use to define the echo canceller
mode for H.323.
0 = Disable
1 = Enable
(default = 1)
3
84-01-25 H.323 Trunk Basic Information
Setup – Echo Canceller Tail Size
Use to define the echo canceller tail
size for H.323.
1 = 4ms
2 = 8ms
3 = 16ms
4 = 32ms
5 = 64ms
6 = 128ms
(default = 6)
3
84-01-26 H.323 Trunk Basic Information
Setup – Echo Canceller NLP
Mode
Use to define the echo canceller
NLP mode for H.323.
0 = Disable
1 = Enable
(default = 1)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3