UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 653
84-01-45 H.323 Trunk Basic Information
Setup – High-speed Signal Data
(FAX Procedure Signal)
Use to define the high-speed signal
data (FAX procedure signal) for
H.323.
0~2
(default = 0)
3
84-01-46 H.323 Trunk Basic Information
Setup – TCF Operation Setting
Use to define the TCF operation
setting for H.323.
1 = Training signal
(TCF) of the fax is
locally generated and
checked.
2 = Training signal
(TCF) of the fax is
sent over the
network
.
(default = 1)
3
84-01-47 H.323 Trunk Basic Information
Setup – The Maximum,
Low-speed Signal Data (Size of
Packet)
Use to define the the maximum,
low-speed signal data (Size of
packet) for H.323.
1~65535 bytes
(default = 1)
3
84-01-48 H.323 Trunk Basic Information
Setup – Network Transmission
Time-out
Use to define the network
transmission time-out for H.323.
10~32000 seconds
(default = 150)
3
84-01-49 H.323 Trunk Basic Information
Setup – Eflag Beginning Timer
Use to define the Eflag beginning
timer for H.323.
0~65535
(default = 2600)
3
84-01-50 H.323 Trunk Basic Information
Setup – Eflag Stop Timer
Use to define the Eflag stop timer
for H.323.
0~65535
(default = 2300)
3
84-01-51 H.323 Trunk Basic Information
Setup – The Former Line
Substitution of Scanning Line
Use to define the the former line
substitution of scanning line for
H.323.
0 = Disable
1 = Enable
(default = 1)
3
84-01-52 H.323 Trunk Basic Information
Setup – Eflag Setting at Head
DIS
Use to define the Eflag setting at
head DIS for H.323.
0 = Disable
1 = Enable
(default = 1)
3
84-01-53 H.323 Trunk Basic Information
Setup – TFOP Protocol
Use to define the TFOP protocol for
H.323.
0 = Disable
1 = Enable
(default = 1)
3
84-01-54 H.323 Trunk Basic Information
Setup – NSF Superscription
Use to define the NSF
superscription for H.323.
0 = Disable
1 = Enable
(default = 0)
3
84-01-55 H.323 Trunk Basic Information
Setup – ECM (Error Correction
Mode)
Use to define the ECM (error
correction mode) for H.323.
0 = Disable
1 = Enable
(default = 1)
3
84-01-56 H.323 Trunk Basic Information
Setup – Enable Modified Read
Code
Use to define the enable modified
read code for H.323.
0 = Disable
1 = Enable
(default = 1)
3
84-01-57 H.323 Trunk Basic Information
Setup – NSF Country Code
Setting
Use to define the NSF country code
setting for H.323.
0~65535
(default = 0)
3
84-01-58 H.323 Trunk Basic Information
Setup – NSF Vendor Code
Setting
Use to define the NSF vendor code
setting for H.323.
0~65535
(default = 0)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3