SV8100 Features and Specifications Manual 2 - 697
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
14-05-01 Trunk Group – Trunk Group
Number
For Auto-Answer of Non-Ringing
Lines, assign trunks to trunk
groups. This is part of Trunk
Group Routing programming.
Trunk Group Number:
0~100 Priority Number:
1~200 (default = Trunk
Group 1, with priority in
ascending order)
3
14-06-01 Trunk Group Routing – Priority
Order Number
Used to set the priority order
number 1~4.
0 = Not Specify1~100 :
(Trunk Group
Number)1001~1100 :
(1000 + Route Table
Number)
Default:
Route 1, Order Number 1
= 1 (Trunk Group 1)
Order Numbers 2, 3, 4 =
0 (Not Specified)
All Other Routes (2~100)
and Order Numbers
(1~4) = 0 (Not Specified)
3
14-07-01 Trunk Access Map Setup For Outgoing Line Preference and
Auto-Answer of Non-Ringing Lines,
set up the Trunk Access Maps.
0 = No access
1 = Outgoing access only
2 = Incoming access only
3 = Access only when
trunk on Hold
4 = Outgoing access and
access when trunk on
Hold
5 = Incoming access and
access when trunk on
Hold
6 = Incoming and
Outgoing access
7 = Incoming access,
outgoing access and
access when trunk on
Hold
Trunk Access Maps:
1~200
Default:
Access Maps 1~200 =
Trunk Ports 1~200
assigned with option 7
access (incoming and
outgoing access and
access when trunk is on
Hold).
3
15-01-02 Basic Extension Data Setup –
Outgoing Trunk Line Preference
Turns On (1) or Off (0) Outgoing
Trunk Line Preference for
extensions.
0 = Off
1 = On
(default = 0)
3
15-02-10 Multiline Telephone Basic Data
Setup – Ringing Line Preference
for Trunk Calls
Enable Idle (0) or Ringing (1) Line
Preference for trunk calls. Program
22-01-01 sets Intercom (0) or trunk
(1) call priority.
0 = Idle
1 = Ringing
(default = 1)