Issue 1.0 UNIVERGE SV8100
2 - 710 Meet Me Paging
Paging, Internal
Programmable Function Keys
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
11-12-21 Service Code Setup (for Service
Access) – Meet-Me Answer to
Specified Internal Paging Group
Use to customize the Service
Codes used for meet-me answer
to specified internal paging group
service access.
MLT, SLT
(default = 764)
3
11-12-22 Service Code Setup (for Service
Access) – Meet-Me Answer to
External Paging
Use to customize the Service
Codes used for meet-me answer
to external paging service access.
MLT, SLT
(default = 765)
3
11-12-23 Service Code Setup (for Service
Access) – Meet-Me Answer in
Same Paging Group
Use to customize the Service
Codes used for meet-me answer
in same paging group service
access.
MLT, SLT
(default = 763)
3
15-07-01 Programmable Function Keys Assign function keys for External
Zone Paging (code 19 + zone),
External All Call Paging (code 20),
Internal Zone Paging (code 21 +
zone) or Meet Me Conference/
Paging Pickup (code 23).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
3
20-10-06 Class of Service Options
(Answer Service) – Meet-Me
Conference and Paging
Turns Off (0) or On (1) an
extension to use Meet-Me
Conference and Paging.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3

Table of Contents