Issue 1.0 UNIVERGE SV8100
2 - 742 Mobile Extension
80-03-03 DTMF Tone Receiver Setup –
Min. Detect Level
For the extension DTMF, the
minimum Detect Level (0-15) for
the DTMF Tone must be set to
allow a minimum detection level of
-25dBm. This entry is dependent
on the Detect Level selected in
Program 80-03-01. For example, if
Detect Level 0 were selected in
Program 80-03-01, the entry in
this option would be 15 for
-25dBm. The system must be
reset for this change to take affect.
0~15
detect level 0:
–10dBm(0) to
–25dBm(15)
detect level 1:
–15dBm(0) to –
30dBm(15)
detect level 2:
–20dBm(0) to –
35dBm(15)
detect level 3:
–25dBm(0) to –
40dBm(15)
detect level 4:
–30dBm(0) to –
45dBm(15)
detect level 5:
–35dBm(0) to –
50dBm(15)
detect level 6:
–40dBm(0) to –
55dBm(15)
detect level 7: -45dBm(0)
to -60dBm(15)
detect level 8: -50dBm(0)
to -65dBm(15)
detect level 9: -55dBm(0)
to -70dBm(15)
detect level 10: -
60dBm(0) to -
75dBm(15)
detect level 11: -
65dBm(0) to -
80dBm(15)
detect level 12: -
70dBm(0) to -
85dBm(15)
detect level 13: -
75dBm(0) to -
90dBm(15)
detect level 14: -
80dBm(0) to -
95dBm(15)
detect level 15: -
85dBm(0) to -
100dBm(15) default:
Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)
Type 3~5 = 10
(-20dBm)