UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 741
20-09-02 Class of Service (Incoming Call
Service) – Caller ID Display
Turns Off (0) or On (1) the Caller
ID display at an extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
22-11-01 DID Translation Number
Conversion – Received Number
Define the digits received by the
system for the telephone number
on which a Mobile Extension user
calls into the system.
Maximum eight digits
(default not assigned)
3
22-11-02 DID Translation Number
Conversion – Target Number
For the DID number defined in
Program 22-11-01, enter the
extension number for the Mobile
Extension user.
Maximum 24 digits
(default not assigned)
3
80-01-01 Service Tone Setup – Tone 44,
External Dial Tone
It is necessary to adjust the DID/
DISA dial tone (tone 44) to a
Repeat Count of 250 (by default,
this is set to 0). The system must
be reset for this change to take
affect.
0~255 (0 = until
On-Hook)
Refer to Table 2-14
Service Tone Setup,
Program 80-01-01 on
page 2-555
3
80-01-01 Service Tone Setup – Tone 57,
Off-Hook Beep Tone - Headset
Earpiece ringing Tone
If required, use this option to
change the tone heard when a
Mobile Extension user goes off
hook to answer a call prior to
pressing *. The system must be
reset for this change to take affect.
0~255 (default 0 = until
On-Hook)
Refer to Table 2-14
Service Tone Setup,
Program 80-01-01 on
page 2-555
3
80-03-01 DTMF Tone Receiver Setup –
Detect Level
Select the Detect Level to be used
for DTMF Tone detection. For the
extension DTMF, this entry must
allow for a detection of -25dBm.
Set the minimum detection level in
Program 80-03-03. The system
must be reset for this change to
take affect.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default: Type 1~5 = 0
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3