UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 761
80-04-09 Call Progress Tone Detector
Setup – OFF maximum time
Use to define the off maximum
time for the Call Progress Tone
Detector.
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 14
(450ms)
Type 3 (RBT) – 115
(3480ms)
Type 4, Type 5 – 0
3
81-11-01 Tie Line Initial Setup – DP
Interdigit Time Selection
Select the DP Interdigit Time
(minimum pause time between
Dial Pulses).
0 = Pattern A
(Pattern A: 10pps – 650
ms,
20pps - 500 ms)
1 = Pattern B
(Pattern B: 10pps – 800
ms,
20pps - 800 ms)
(default = 1)
3
81-11-02 Tie Line Initial Setup – Prepause
Time Selection
Specify the loop open time for a
hookflash signal sent to the Tie
Line when the Recall key on a
multiline terminal is pressed. A
single line telephone generates a
hookflash to the Tie Line when a
single line telephone hookflash is
assigned.
1~4
(1~4 = 0.5~2.0 seconds)
(5~15 = 3.0~13 seconds)
(0 = No Setting)
(default = 0)
3
81-11-03 Tie Line Initial Setup – Tie Line
Answer Detect Time Selection
Specify the time before a SV8100
System answer (off-hook) is
recognized as an answer.
0~15
(130 ms~1950 ms)
(0 = No Setting)
[default = 4 (520 ms)]
3
81-11-04 Tie Line Initial Setup – Tie Line
Release Detect Time Selection
Specify the before the circuit
disconnect detected on the Tie
Line on the distant system side is
recognized as Tie Line release.
0~15
(130 ms~1950 ms)
(0 = No Setting)
[default = 4 (520 ms)]
3
81-11-05 Tie Line Initial Setup – Incoming
Signal Detect Time Selection
Specify the time after the incoming
signal from another system is
detected before the acknowledge
signal is sent out.
[Wink Start]
1~15
(130 ms~1950 ms)
(0 = No Setting)
[Delay]
1~15
(30 ms~450 ms)
(0 = No Setting)
Default:
[Wink Start] 3 (390 ms)
[Delay] 3 (90 ms)
3
81-11-06 Tie Line Initial Setup – Loop
Off-Guard Time Selection
Assign the loop off-guard time to
prevent noise that could cause the
system to be unable to answer an
incoming Tie Line.
1~4
(0.5 sec~2.0 seconds)
5~15
(3 sec~13 seconds)
(0 = No Setting)
[default = 4 (2.0 ms)]
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3