Issue 1.0 UNIVERGE SV8100
2 - 762 Multiple Trunk Types
Operation
None
81-11-07 Tie Line Initial Setup – Length of
Wink Signal Selection
Specify the time a wink pulse is
sent to another system.
0~15
(30 ms~480 ms)
[default = 5 (180 ms)]
3
81-11-08 Tie Line Initial Setup – Length of
Delay Signal Selection
Specify the time a delay pulse is
sent to another system.
1~15
(300 ms~4.5 seconds)
(0 = No Setting)
[default = 1 (300 ms)]
3
81-11-09 Tie Line Initial Setup – Incoming
Interdigit Timeout Selection
Specify the time, in seconds, that
an address signal is missing
during the incoming call detection
process before an error tone is
returned to the other system.
0 = 8
1~15
(1~15 seconds)
[default = 6 (6 seconds)]
3
81-11-10 Tie Line Initial Setup – Wink/
Delay Signal Detect Timeout
Selection
Specify a maximum time, in
seconds, for receiving an
acknowledgment signal from a
distant system before sending a
busy tone.
0 = 8
1~15
(1~15 seconds)
[default = 7 (7 seconds)]
3
81-11-11 Tie Line Initial Setup –
Disconnect Recognition Time
Selection
Specify the minimum time before a
disconnected circuit can be
accessed again.
1~15
(0.1~1.5 seconds)
(0 = No Setting)
[default = 3 (0.3
seconds)]
3
81-11-12 Tie Line Initial Setup – Automatic
Release Signal Detection
Selection
Specify the signal detection time
for release of a Tie Line after a
disconnect signal is received from
the distant Central Office or PBX.
1~14
(50~700 ms)
15 = (No Limit)
(0 = No Setting)
[default = 7 (350 ms)]
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3