Issue 1.0 UNIVERGE SV8100
2 - 766 Music on Hold
14-08-01 Music on Hold Source for Trunks –
MOH Type
For each trunk, set the Music on
Hold source.
0 = Internal/External MOH
1 = Customer Provided
Source Connected to
BGM Port
2 = Customer Provided
Source Connected to ACI
Port
(default = 0)
3
14-08-02 Music on Hold Source Port
Number – Source Port Number
If the MOH type is 2 in Program
14-08-01, for each trunk enter the
ACI source port number (1~96).
Source port 0-96 (default =
0)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
3
20-07-02 Class of Service Options
(Administrator Level) – Changing
the Music on Hold Tone
Turns Off or On an extension ability
to change the Music on Hold tone.
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
3
22-11-09 DID Translation Number
Conversion – Music On Hold
Source
For each DID Translation Table
entry (1~2000), specify the source
of music to be used for DID trunks.
0 = IC/MOH Port
1 = BGM Port
2 = ACI Port
(default = 0)
3
22-11-10 DID Translation Number
Conversion – ACI Music Source
Port
For each DID Translation Table
entry (1~2000), if item 2 is selected
in Program 22-11-09, specify the
port to be used for the source of
music heard on DID trunks.
When a sound source type
is 2 in above : (0~96)
(default = 0)
3
80-01-01 Service Tone Setup – Music On
Hold Tone (Service Tone 64)
Used to customize the repeat count
for the musing on hold tone if
Program 10-01-01 is set to 2.
0~255 (0=Until On-Hook)
(Default 0)
Refer to Table 2-14
Service Tone Setup,
Program 80-01-01 on
page 2-555
3
80-01-02 Basic Tone Number Used to customize the basic tone
number for the musing on hold tone
if Program 10-01-01 is set to 2.
1~33
(0 = No Tone)
(33=Default Time Slot)
3
80-01-03 Duration Count Used to customize the duration
count for the musing on hold tone if
Program 10-01-01 is set to 2.
1~255 (100~25500ms)
3
80-01-04 Gain Level (dB) Used to customize the Gain Level
for the musing on hold tone if
Program 10-01-01 is set to 2.
1~63 (-15.5 ~ +15.5)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3