Issue 1.0 UNIVERGE SV8100
2 - 780 Night Service
12-07-01 Text Data for Night Mode Create an original text message
which is displayed on an LCD of
multiline terminal in each Night
Mode.
Night Mode Service
Group Number:
01~32
Day/Night Mode: 1~8
Text Message:
Maximum 12
Characters (alphabetic
or numeric)
Default Text Messages
for Day/Night Modes:
Mode 1 = No Setting
Mode 2 = <Night>
Mode 3 = <Midnight>
Mode 4 = <Rest>
Mode 5 = <Day2>
Mode 6 = <Night2>
Mode 7 = <Midnight2>
Mode 8 = <Rest2>
3
12-08-01 Night Mode Service Range For each Night Mode Group
(01~32), determine how many night
modes a user toggles through when
the Night Mode key is pressed.
Night Mode Service
Group Number:
01~32
Range: 2~8
(default Range = 2)
3
14-07-01 Trunk Access Map Setup To allow for Universal Night Answer
(UNA) answering, set up the Trunk
Access Maps (1~200). For UNA,
extension must have incoming
access to trunk ringing the External
Paging speakers.
0 = No access
1 = Outgoing access
only
2 = Incoming access
only
3 = Access only when
trunk on Hold
4 = Outgoing access
and access when trunk
on Hold
5 = Incoming access
and access when trunk
on Hold
6 = Incoming and
Outgoing access
7 = Incoming access,
outgoing access and
access when trunk
on Hold
Trunk Access Maps:
1~200
Default:
Access Maps 1~200 =
Trunk Ports 1~200
assigned with option 7
access (incoming and
outgoing access and
access when trunk is
on Hold).
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3