Issue 1.0 UNIVERGE SV8100
2 - 788 Off-Hook Signaling
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
11-12-03 Service Code Setup (for Service
Access) – Override (Off-Hook
Signaling)
Assign a service code (709 by
default) to be used for Off-Hook
Signaling Override.
MLT, SLT
(default = 709)
3
11-16-04 Single Digit Service Code Setup –
Intercom Off-Hook Signaling
Assign a one-digit service code to
be used for Off-Hook Signaling.
(default = )
3
15-02-12 Multiline Telephone Basic Data
Setup – Off-Hook Ringing
For each extension, set Off-Hook
Ringing type: 0 (muted), 1 (none), 3
(beep in speaker), 4 (beep in
handset), 5 (Speaker & Handset
Beep). DID, DNIS and DIL trunks
can use any of the four options -
normal/ring group trunks can only
use options “0” or “1”.
0 = Muted Off-Hook
Ringing
1 = No Off-Hook Ringing
2 = Not Used
3 = Beep in Speaker (SP)
4 = Beep in Handset (HS)
5 = Speaker & Handset
Beep
(default = 5)
3
15-07-01 Programmable Function Keys Assign a function key for Off-Hook
Signaling (code 33).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
3
20-09-07 Class of Service Options
(Incoming Call Service) – Call
Queuing
Turns Off (0) or On (1) an extension
ability to have calls queued if a call
rings the extension when it is busy.
Must be set to 1 to enable
automatic Off-Hook Signaling.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-05 Class of Service Options
(Supplementary Service) –
Intercom Off-Hook Signaling
Turns On (1) or Off (0) the ability of
an extension to receive Off-Hook
Signals.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3