Loading...
UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 793
Operation
Programmable Function Keys
To define a Programmable Function Key as a One-Touch Key:
1. Dial the service code for Function Key Programming (Program 11-11-17, 751 by default).
2. Press the key to be defined.
3. Dial 01 (DSS/One-Touch Key Operation).
4. For Direct Station Selection (Extension):
a. Dial extension number you want assigned to that key.
b. Press Hold.
c. Press Speaker.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
15-07-01 Programmable Function Keys Define a Programmable Function
Key for One-Touch Calling by
defining the key as a DSS/
One-Touch key (01).
For Line Keys: 1~48
0 ~ 99 (Normal Function
Code)
(default = Service Code
751)*
00
~
99 (Appearance
Function Code) (default =
Service Code 752)
3
11-11-17 Service Code Setup (for Setup/
Entry Operation)
– Programmable
Function Key Programming (2-
Digit Service Codes)
Use this option to set the service
code (default 751) to assign 2-digit
function codes to the Function
keys.
MLT
(default = 751)
3
20-13-18 Class of Service Options
(Supplementary Service) –
Programmable Function Key
Programming (General Level)
Turns Off (0) or On (1) an
extension user ability to program
General function keys using
Service Code 751 (by default).
(Refer to Program 20-07-10 for
Service Code 752.)
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
30-03-01 DSS Console Key Assignment Customize DSS Console keys to
function as DSS keys, Service
Code keys, Programmable
Function Keys, and One-Touch
Calling keys.
When programming a feature
within a One-Touch Key, refer to
the feature description for
additional programming options.
Key Number
001~500
0~99 (General Functional
Level)
97 = Door Box Access
key (additional data: 1~8
Door Box No.)
00 ~ 99
(Appearance Functional
Level)
3

Table of Contents