UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 849
14-07-01 Trunk Access Map Setup – Trunk
Port Number
For outgoing Prime Line selection,
assign each Prime Line trunk to a
different Access Map and deny
outbound access to all trunks
except the Prime Line trunk.
0 = No access
1 = Outgoing access only
2 = Incoming access only
3 = Access only when
trunk on Hold
4 = Outgoing access and
access when trunk on
Hold
5 = Incoming access and
access when trunk on
Hold
6 = Incoming and
Outgoing access
7 = Incoming access,
outgoing access and
access when trunk on
Hold
Trunk Access Maps:
1~200
Default:
Access Maps 1~200 =
Trunk Ports 1~200
assigned with option 7
access (incoming and
outgoing access and
access when trunk is on
Hold)
3
15-01-02 Basic Extension Data Setup –
Outgoing Trunk Line Preference
Turns On (1) or Off (0) Outgoing
Trunk Line Preference for
extensions.
0 = Off
1 = On
(default = 0)
3
15-02-10 Multiline Telephone Basic Data
Setup – Ringing Line Preference
for Trunk Calls
Enter 1 if lifting the handset should
answer ringing Prime Line; enter 0
to seize idle line appearance.
0 = Idle (Off)
1 = Ringing (On)
(default = 1)
3
15-06-01 Trunk Access Map for
Extensions
Set assignment so extension(s)
can have access to Prime Line.
Deny outbound access to
extensions that should not have
Prime Line.
Trunk Access Maps:
1~200
(default = 1)
3
21-02-01 Trunk Group Routing for
Extensions
Assign extension(s) to a Prime
Line route for outgoing Prime Line
access.
Trunk Groups: 1~100
Day/Night Mode: 1~8
Route Table Number:
0~100
(0 = No Setting)
(default = 1)
3
22-01-01 System Options for Incoming
Calls – Incoming Call Priority
Use this option to determine if
Intercom calls or trunk calls have
answer priority when both are
ringing simultaneously.
0 = Intercom call priority
1 = Trunk call priority
(default = 1)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents

Other manuals for NEC Univerge SV8100