20-03-05 System Options for Single Line
Telephones – SLT Operation Mode
Used to define the Operation Mode
for SLT terminals.
0 = Normal Mode
1 = Extended Mode1
2 = Extended Mode2
(default = 0)
3
20-03-06 System Options for Single Line
Telephones – Headset Ringing
Start Time
Define the headset ringing start
time. After this time expires from the
time when a single line telephone is
off-hook, the system sets the single
line telephone to headset ringing
mode.
0~64800 seconds
(default = 5 seconds)
3
20-03-07 System Options for Single Line
Telephones – Trunk Call Dial
Forced Sending Start Time
(Forced Dial)
Used to define the Trunk Call Dial
Forced Sending Start Time.
0~64800 seconds
(default = 0)
3
20-06-01 Class of Service for Extensions Assign a unique Class of Service for
Dual OPX telephones only when
using Continued Dialing.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 = Class
15
All other extension port =
Class 1
3
20-13-13 Class of Service Options
(Supplementary Service) –
Continued Dialing (DTMF) Signal
on ICM Call
Turns Off (0) or On (1) an extension
user ability to use Continued
Dialing, which allows DTMF signal
sending while talking on extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-15-01 Ring Cycle Setup – Normal
Incoming Call on Trunk
Define the ringing cycle (1~13) for
normal incoming trunk calls (DIL,
ring group, etc.).
Ringing Cycle = 1~13
(default = 3)
3
20-15-03 Ring Cycle Setup – Incoming
Internal Call
Define the ringing cycle (1~13) for
ICM calls.
Ringing Cycle = 1~13
(default = 3)
3
20-15-05 Ring Cycle Setup – DID/DDI Define the ringing cycle (1~13) for
DID calls.
Ringing Cycle = 1~13
(default = 8)
3
80-03-01 DTMF Tone Receiver Setup –
Detect Level
Use Items 11~32 to set the criteria
for dial tone detection for outgoing
ARS calls.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default: Type 1~5 = 0
3
80-03-02 DTMF Tone Receiver Setup – Start
delay time
Use this option to define the start
delay time for DTMF Tone Receiver.
0~255
(0.25 ms ~ 64 ms)
default:
Type 1~5 = 0
3