EasyManua.ls Logo

NEC Univerge SV8100 - Page 989

NEC Univerge SV8100
1386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 965
80-03-01 DTMF Tone Receiver Setup –
Detect Level
Use to define the detect levels for
the DTMF Tone Receiver.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default: Type 1~5 = 0
3
80-03-02 DTMF Tone Receiver Setup – Start
delay time
Use to define the start delay times
for the DTMF Tone Receiver.
0~255 (0.25 ms ~ 64 ms)
(default: Type 1~5 = 0)
3
80-03-03 DTMF Tone Receiver Setup – Min.
detect level
Use to define the minimum detect
levels for the DTMF Tone Receiver.
0~15
detect level 0:
–10dBm(0) to
–25dBm(15)
detect level 1:
–15dBm(0) to
–30dBm(15)
detect level 2:
–20dBm(0) to
–35dBm(15)
detect level 3:
–25dBm(0) to
–40dBm(15)
detect level 4:
–30dBm(0) to
–45dBm(15)
detect level 5:
–35dBm(0) to
–50dBm(15)
detect level 6:
–40dBm(0) to
–55dBm(15)
detect level 7: -45dBm(0)
to -60dBm(15)
detect level 8: -50dBm(0)
to -65dBm(15)
detect level 9: -55dBm(0)
to -70dBm(15)
detect level 10: -
60dBm(0) to -
75dBm(15)
detect level 11: -
65dBm(0) to -
80dBm(15)
detect level 12: -
70dBm(0) to -
85dBm(15)
detect level 13: -
75dBm(0) to -
90dBm(15)
detect level 14: -
80dBm(0) to -
95dBm(15)
detect level 15: -
85dBm(0) to -
100dBm(15) default:
Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)
Type 3~5 = 10
(-20dBm)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents

Other manuals for NEC Univerge SV8100