80-03-01 DTMF Tone Receiver Setup –
Detect Level
Use to define the detect levels for
the DTMF Tone Receiver.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default: Type 1~5 = 0
3
80-03-02 DTMF Tone Receiver Setup – Start
delay time
Use to define the start delay times
for the DTMF Tone Receiver.
0~255 (0.25 ms ~ 64 ms)
(default: Type 1~5 = 0)
3
80-03-03 DTMF Tone Receiver Setup – Min.
detect level
Use to define the minimum detect
levels for the DTMF Tone Receiver.
0~15
detect level 0:
–10dBm(0) to
–25dBm(15)
detect level 1:
–15dBm(0) to
–30dBm(15)
detect level 2:
–20dBm(0) to
–35dBm(15)
detect level 3:
–25dBm(0) to
–40dBm(15)
detect level 4:
–30dBm(0) to
–45dBm(15)
detect level 5:
–35dBm(0) to
–50dBm(15)
detect level 6:
–40dBm(0) to
–55dBm(15)
detect level 7: -45dBm(0)
to -60dBm(15)
detect level 8: -50dBm(0)
to -65dBm(15)
detect level 9: -55dBm(0)
to -70dBm(15)
detect level 10: -
60dBm(0) to -
75dBm(15)
detect level 11: -
65dBm(0) to -
80dBm(15)
detect level 12: -
70dBm(0) to -
85dBm(15)
detect level 13: -
75dBm(0) to -
90dBm(15)
detect level 14: -
80dBm(0) to -
95dBm(15)
detect level 15: -
85dBm(0) to -
100dBm(15) default:
Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)
Type 3~5 = 10
(-20dBm)
3
Program
Number
Program Name Description/Comments Assigned Data
Level