Chapter 5 System Data Mode
5-9 NWA-033628-001 Rev.1.0
Using System Data Mode
: Default
Y 1ST DATA 2ND DATA
No. MEANING
DATA MEANING DATA MEANING
00 TDM terminal registration XXYYZZ Physical Port number
XX: Unit number (01-50)
YY: Slot number (01-18)
ZZ: Circuit number
(01-32)
FX
F
XXXX
XXXX
Multiline Terminal station num-
ber X-XXXXXXXX represents
My Line number.
X: 0-9, A (*), B (#)
NONE No data
01 IP terminal registration 0000
1499
Virtual Port number
(for IP terminal)
FX
F
XXXX
XXXX
IP Station/Multiline Terminal
station number
X: 0-9, A (*), B (#)
E100
E131
DSS Console number (00-31)
EC00
EC31
Add-on Module number
NONE No data
02 IPT (P2P CCIS) registra-
tion
000
511
Virtual Port number
(for IPT [P2P CCIS])
D000
D511
Trunk No.
NONE No data
03 SIP trunk registration 01YYY Virtual Port number
(for SIP trunk)
01 : Unit No.
YYY : Port No.
000 : Port No. for
control channel
001-096: Port No. for
voice channel
D000
D511
Trunk No.
NONE No data
04 Wireless terminal registra-
tion
000
511
Virtual Port number
(for Wireless terminal)
X
XXXX
XXXX
PHS/Wireless telephone station
No.
X: 0-9, A (*), B (#)
NONE No data
~
~
~~~
~
~ ~
~
~