Chapter 6 Command Mode
6-4 NWA-033628-001 Rev.1.0
Using Command Mode
Command Entry
Commands are entered in combination of system data (command, first data, second data) and control
codes.
<Control Code List>
There are three modes of control code entry, as follows:
Classic Mode : Control codes entry that are assigned to [.], [Space], [/] and other keys.
Standard Mode : Control codes entry that are assigned to a PC’s function keys.
Enter Mode : Control codes entry that are assigned to [Enter] key.
Continued on next page
No. Item Description
(4) Entry mode/Charac-
ter mode display
Displays the present control code entry mode (Classic/Standard/Enter)
and the ON/OFF states of the character mode.
The ON/OFF states of the character mode have the following mean-
ings:
- Character mode
OFF
: Only 0 to 9 and A to F comma (,), period (.) can
be entered (a to f are automatically converted to
A to F). The control key is inoperable.
- Character mode
ON
: All data can be entered. The control code is oper-
able.
Function key F12 is used to switch the character mode ON and OFF.
Control
code
Meaning
Control keys
Classic
Mode
Standard
Mode
Enter Mode
[ST] Start of command entry. [/] (slash) [F9] [Esc]
[DE] End of command entry
End of first data entry
Read second data that has been set
in input first data.
[Space] [F8] [Enter]
[EXE] Set second data. [.] (period) [F2] [Enter]
[CE] Cancel entries. [:] (colon) [F3] []
[S] Read the second data that has been
set as the next batch of first data.
[Enter] [F4] [
]