Maintenance routines
FIGHTER 360P
For Home Owners
8
The building’s ventilation devices should be cleaned
regularly with a small brush to keep the correct venti-
lation.
The device settings must not be changed.
NOTE! If you take down more than one ventilation
device for cleaning, do not mix them up.
Check that the ventilation opening (84), behind the
lower front cover, is not blocked. Clean if necessary.
The heat pump's air filter needs to be cleaned regu-
larly (approximately 4 – 5 times per year). The interval
between cleaning operations varies and depends on
the amount of dust in the exhaust air.
■ Set the switch to “0”.
■ Open the upper front cover by pulling it out by the
lower edge, then lifting it up.
■ Pull out the holder (78).
■ Take out the filter and shake off any dirt.
Check that the filter is not damaged. New original
filters can be ordered from NIBE.
■ Assembly takes place in the reverse order.
The cleaning time intervals vary depending on the
amount of dust in the exhaust air.
Also see the section, Alarm indications in the display,
FILTER MONITOR.
The heat pump and its ventilation ducting require some
regular maintenance when the following points should
be checked.
The numbers in brackets refer to the section Compo-
nent locations.
Cleaning the air filter