Control
39
For the Installer
FIGHTER 360P
9.0 Service menu
Menu 9.1.8 Time factor el.heat.
The time factor of the immersion heater since first start
up is shown here. The value is saved in the microproc-
essor and thus is not reset even when the heat pump is
switched off using the main power switch.
0
Time factor el.heat.
9.1.8
Menu 9.1.6 Factory pre-set
Select Yes and press the enter button to restore the
heat pump to the factory settings.
Once the factory settings have been restored the heat
pump returns to Menu 1.0.
No
Factory pre-set
9.1.6
S
Menu 9.1.7 Trend calc. limit
At what outdoor temperature trend calculating ceases
is selected here. Below this limit trend calculating is
not used to enable the additional heat. The value is
adjustable between 0 and 20 °C.
5°C
Trend calc. limit
9.1.7
S
S
Menu 9.1.0 Operating settings
Settings regarding additional heat, floor drying and a
return to the factory settings can be made on the sub-
menus in this menu.
Operating settings
9.1.0
Menu 9.1.1 Electric boiler
The heat pump can be set in electric boiler mode from
here. This mode means the compressor is blocked, but
all other components function as normal. This mode
can be activated if a fault is discovered on the com-
pressor or any other component in the cooling circuit.
Note no energy savings are made in this mode. Once
the fault has been rectified the heat pump should be
switched to normal mode again. The electric boiler
mode is activated when Yes is shown on the display
screen, otherwise No is shown. When the electric boil-
er mode is activated, the immersion heater respective
circulation pump cannot be blocked with the operating
mode button.
No
Electric boiler
9.1.1
S
S
Off
Shunt group 2
9.1.2
S
Menu 9.1.3 RCU
The RCU (accessory) is set On or Off here.
Off
RCU
9.1.3
S
Menu 9.1.4 Circulation pump
The operating mode of the circulation pump for the
heating system can be force controlled from this menu.
When On is selected the circulation pump runs con-
stantly. When Off is selected the circulation pump is
blocked. Note however that a change in the operating
mode using the operating mode button disables the
change made in this menu.
Off
Circulation pump
9.1.4
S
Menu 9.1.5 Circulation pump 2
The operating mode for circulation pump 2 for the
heating system can be force-controlled from this menu.
When On is selected the circulation pump runs con-
stantly. When Off is selected the circulation pump is
blocked. Note however that a change in the operating
mode using the operating mode button disables the
change made in this menu.
Off
Circulation pump 2
9.1.5
S
Menu 9.1.2 Shunt group 2
Here you select whether shunt group 2 is connected.
NOTE! Requires accessories.