EasyManua.ls Logo

Nibe FIGHTER 360P - Page 42

Nibe FIGHTER 360P
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control
FIGHTER 360P
For the Installer
40
Menu 9.1.9 Quickstart comp.
Select Yes in order to reduce the pressure-compensat-
ing time to 0 and in doing so permit a quick start of the
compressor.
NOTE! The setting returns to No as soon as the heat
pump has implemented the action.
No
Quickstart comp.
9.1.9
Menu 9.2.0 Floor drying setting
Pressing the enter button takes you to sub-menus for
the floor drying settings.
Floor drying setting
9.2.0
Menu 9.2.1 Op-mode floor drying
The operating mode for the floor drying function is set
here. Selectable modes are:
Off: Normal operation, i.e. the floor drying function is
switched off.
Own program: Two fixed temperatures in two periods
are adjustable in menu 9.2.3 to 9.2.6.
Fixed program: The flow temperature starts day 0 at
20 degrees and increases each day by 5 degrees. Day
5 the temperature has reached 45 degrees, which is
maintained on days 6 and 7. The program is ended on
days 8 to 12 with the temperature dropping by 5
degrees each day.
Off
Op-mode floor drying
9.2.1
Menu 9.1.10 Quickstart el.heater
Normally the electrical output of the immersion heat-
ers is limited to a maximum of 6 kW for the first two
hours after the heat pump has been started, i.e. after
the main power switch has been set to 1.
Selecting Yes in this menu disengages the two-hour
delay.
NOTE! The setting returns to No as soon as the heat
pump has implemented the action.
No
Quickstart el.heater
9.1.10
Menu 9.1.16 Return
Return to Menu 9.1.0.
Return
9.1.16
9.0 Service menu
S
S
S
S
S
Menu 9.1.14 Room control mode
Any room sensors are activated here. The menu can
be set to “Off”, “RG05”, “RG10” or "RE10". Accesso-
ries are needed.
Off
Room control mode
9.1.14
S
Menu 9.1.11 Delay compressor
Displays the time to next possible compressor start.
Delay compressor
9.1.11
S
Menu 9.1.12 Time HW to heat
The time between hot water charging and heating is
set here.
The time is adjustable between 1 and 120 minutes.
Time HW to heat
9.1.12
S
Menu 9.1.13 Operating status
Displays the current operating status (How water/
Switch status/Heating).
Operating status
9.1.13
S
Menu 9.1.15 Temperature limiter
Here the temperature limiter alarm can be selected to
be activated or not. Note that the temperature limiter is
always active – only the alarm indication can be turned
off.
On
Temp limiter
9.1.15
S