53
For the Installer
Technical specifications
53
FIGHTER 360P
IP 21
Enclosure class IP 21
Required ceiling height 2 185 mm
Depth 615 mm
Volume total 240 litres
Volume water heater 170 litres
Output immersion heater 13,5 kW (switchable)
Rated output exhaust air fan 170 W
Max pressure in double jacket volume 0,25 MPa (2.5 (bar)
Breaking value, low pressure pressostat 0,15 MPa (1.5 (bar)
Refrigerant volume 420 g
Sound power level* 44–48 dB(A)
Height (excl. foot: 15 – 40 mm) 2 095 mm
Width 600 mm
Weight 205 kg
Volume double jacket 70 litres
Supply voltage 400 V~ 3-phase + N
Rated output, circulation pump 100 W
Rated output, compressor 650 W
Max pressure in storage heater 0,9 MPa (9 (bar)
Breaking value, high pressure pressostat 2,45 MPa (24.5 (bar)
Design pressure in double jacket volume 0,25 MPa (2.5 (bar)
Refrigerant type R290 (propane)
Sound level in the boiler house** 40–44 dB(A)
Article number 089 570
* A-weighted sound power level (L
wA
). The value varies with the selected fan curve.
** A-weighted sound pressure level (L
pA
). The value varies with the room’s damping capacity.
These values apply with a damping of 4 dB.
Enclosed kit